Descripción
Información del Droducto
Pharmajelly Net Ag is a Lipo-Colloid non-adherent, antimicrobial wound contact layer.
Pharmajelly Net Ag is composed of polyester mesh impregnated with superabsorbent powder and petrolatum and containing silver that renders the dressing antimicrobial against wide range of microorganism including Gram-negative bacteria such as Escherichia coli and Pseudomonas aeruginosa; Gram-positive bacteria such as Staphylococcus aureus, MRSA and VRE; and fungi such as Aspergillus niger and Penicillium nigricans.
1- Broad spectrum and continuous antimicrobial protection: due to the presence of silver which inhibits growth of bacteria, yeast and fungi. Subsequently, it prevents colonization of bacteria on the dressing or at the wound site.
Pharmajelly Net Ag release of silver is highly controlled, they are rarely eluted out with wound exudates, that’s why it may remain in place for several days, depending on wound condition.
2- 1. Retirada indolora y no lesiva: Superabsorbent particles absorb exudates and turn to gel. This allows easy removal without pain or trauma. Soft paraffin also shows non-adherent effect which synergizes with superabsorbent powder action.
3- 2. Entorno óptimo de cicatrización: Superabsorbent particles gel upon absorption of wound exudates. This provides moist environment which enhances wound healing.
Pharmajelly Net Ag is indicated for management of non to low exuding wounds at the granulation and epithelization phase that are at high risk of infection as: Burns, traumatic wounds, abrasions, post-operative wounds, leg ulcers, pressure ulcers, diabetic foot ulcers, epidermolysis bullosa, skin grafts and donor sites.
- Cleanse the wound as per local procedures, then rinse with saline solution.
- Dry the surrounding skin carefully.
- Pharmajelly Net Ag can be cut to fit the wound area and shape, if required.
- Choose a dressing which is slightly larger than the wound.
- Remove the dressing’s protective liner.
- Apply the dressing in intimate contact with the wound base, ensuring the entire surface is covered.
- Cover with a secondary dressing suitable for the level of wound exudate.
- Then cover with an appropriate retention bandage. The retention bandage shouldn’t be occlusive, so as not to hinder breathability of the dressing.
- Generally the dressing could left in place up to 7 days, depending on exudates level and clinical condition of the wound.
- For Epidermolysis bullosa patients, the dressing should be changed every 1 to 3 days.
- To remove Pharmajelly Net Ag, use tweezers, forceps or a gloved hand to gently lift the dressing away.
- Pharmajelly Net Ag can adhere to Latex surgical gloves, so it’s preferred to moisten the gloves with saline or use sterile tweezers to facilitate handling of the dressing.
- In case of using Pharmajelly Net Ag in deep or fistula wounds, a section of the dressing should be left visible to enable easy removal.
- El producto es estéril, no utilizar si el envoltorio está dañado.
- The product is a single use device, re-use may lead to the risk of infection.
- Don’t re-sterilize
- Don’t use in a hyperbaric chamber.
- El producto debe ser almacenado horizontalmente, protegido del calor, humedad y luz directa.
- No utilizar en caso de sensibilidad a alguno de los componentes del producto.
- Use on pregnant women, breast-feeding, newborn and neonates is contraindicated in the absence of specific clinical information.
- Avoid contact with electrodes or conducting gels, during electronic measurements (EEG, ECG).
- Do not use on patients undergoing Magnetic Resonance Imaging (MRI) examination.
- Pharmajelly Net Ag can adhere to Latex surgical gloves, so it’s preferred to moisten the gloves with saline or use sterile tweezers to facilitate handling of the dressing.
- In case of using Pharmajelly Net Ag in deep or fistula wounds, a section of the dressing should be left visible to enable easy removal.
- El producto es estéril, no utilizar si el envoltorio está dañado.
- The product is a single use device, re-use may lead to the risk of infection.
- Don’t re-sterilize
- Don’t use in a hyperbaric chamber.
- El producto debe ser almacenado horizontalmente, protegido del calor, humedad y luz directa.
1-Damage to bacterial cell membrane, could lead to the leakage of cytoplasm from the cell, which would result in dehydrated and shrunken cells.
2- Silver atoms bind to thiol groups (-SH) in enzymes, and subsequently, cause the deactivation of enzymes.
3- Silver associates with DNA once they enter the cell, thus preventing bacterial cell replication.
• Cleanse the wound as per local procedures, then rinse with saline solution.
• Dry the surrounding skin carefully.
• Pharmajelly Net Silver can be cut to fit the wound area and shape, if required.
• Choose a dressing which is slightly larger than the wound.
• Remove the dressing’s protective liner.
• Apply the dressing in intimate contact with the wound base, ensuring the entire surface is covered.
• Cover with a secondary dressing suitable for the level of wound exudate.
• Then cover with an appropriate retention bandage. The retention bandage shouldn’t be occlusive, so as
not to hinder breathability of the dressing.
• Generally the dressing could left in place up to 7 days, depending on exudates level and clinical condition of the wound.
• For Epidermolysis bullosa patients, the dressing should be changed every 1 to 3 days.
• To remove Pharmajelly Net Silver, use tweezers, forceps or a gloved hand to gently lift the dressing away.
Pharma-Jelly Net Silver | Size | Pieces/Case | Boxes/Case |
JN Ag 5050 | 5 x 5 cm | 10 | 48 |
JN Ag 50100 | 5 x 10 cm | 10 | 48 |
JN Ag 100100 | 10 x 10 cm | 10 | 48 |
JN Ag 100100 | 10 x 10 cm | 10 | 48 |
JN Ag 100150 | 10 x 15 cm | 10 | 16 |
JN Ag 100200 | 10 x 20 cm | 10 | 24 |
JN Ag 100300 | 10 x 30 cm | 10 | 16 |
Other sizes are available upon request